The CDA-1 is the central controller of the TrolMaster Carbon-X CO₂ safety system, designed to provide essential CO₂ level monitoring for up to 13 individual zones or rooms. This professional-grade system is ideal for indoor environments using supplemental CO₂ and helps ensure compliance with local safety regulations.
The Carbon-X allows for both high-level alerts (up to 30,000ppm) and low-level warnings (5,000ppm). These thresholds are fully adjustable, giving users the flexibility to match system behavior to regional guidelines and facility requirements.
Beyond monitoring, the Carbon-X can also control multiple safety-related devices such as:
-
Exhaust fans
-
Dampers
-
Main CO₂ solenoid valves
-
Fire alarm system interfaces (via connection to the facility’s fire panel)
By wiring the main CO₂ solenoid in line with a system control module, the Carbon-X can automatically cut off CO₂ flow if unsafe conditions are detected. Device settings are user-configurable, allowing for straightforward customization across your facility.
Each monitored room requires a connected audio-visual alarm to clearly indicate current CO₂ levels and to notify staff whether it's safe to enter the area.
The TrolMaster app provides remote access to the system, including real-time CO₂ readings and instant alerts when CO₂ concentrations exceed your custom-set limits.
As the central hub of the Carbon-X system, the CDA-1 plays a critical role in both safety and automation—making it a must-have solution for operations utilizing CO₂ enrichment indoors.
Features & Benefits:
- Multiple Zones
- Customizable
- Plug and Play
- App connectivity
The TrolMaster Carbon-X system is designed to protect customers and workers near commercial indoor growing areas that use supplemental CO2, satisfying all local and state regulations. The system has a modular structure, allowing you to customize the system to fit your unique requirements, being able to monitor up to 13 zones.
The Carbon-X system offers both high level alerts, as well as low level alerts. The sensors will constantly monitor the CO2 level of the areas. If unsafe levels of CO2 are detected, the system can shut down CO2 flow, vent the area, turn on visual and audible alarms and even send signals to a fire alarm panel.
The system can control up to 40 outputs total. Each output can be linked to an individual sensor or all sensors for a customized programming. There are five types of outputs that can be connected to the system.
The AS-1 and AS-2 CO2 Alarm Stations are audio-visual alarm modules.
The DSE-1 CO2 Emergency Stop Station controls the main Co2 solenoid. It will automatically shut it off if any fault or high CO2 level is detected
The DSC-1 is a 120V controlled outlet that turns on devices like ventilation fans if any fault or high CO2 level is detected.
The DSD-1 is a Dry Contact output. Both N/O and N/C connections are provided on the DSD-1 and it can interface to the fire alarm panel.
The Carbon-X system also provides internet connectivity to a cloud service that will send push alerts to Trolmaster’s smart phone APP and send alert emails to email accounts.
Package Content:
- 1x CO2 Alarm System (CDA-1)
- 2x16ft RJ12 Cable
- 1x12V Power Adapter
Specifications
- Input Voltage:100-240VAC, 50/60Hz
- Max Sensors:13 pcs per Alarm channel
- Max controlled output:40 pcs
- Working Temperature: 32-122°F
- Working Humidity: <90%
TrolMaster Carbon-X CO2 Alarm System User Manual
TrolMaster Carbon-X CO2 Alarm System Cut Sheet
TrolMaster Carbon-X CO2 Alarm System Sequence of Events
TrolMaster Carbon-X CO2 Alarm System Firmware Update
Videos
Q&A
Common questions about the TrolMaster Carbon-X CO2 Alarm System!
Q: What is the TrolMaster Carbon-X system used for?
A: The Carbon-X system is designed to monitor and manage CO₂ safety levels in indoor grow facilities. It helps ensure compliance with safety regulations by providing automatic shutoffs, real-time monitoring, and alert systems for up to 13 individual rooms or zones.
Q: What is the CDA-1 in the Carbon-X system?
A: The CDA-1 is the main controller of the Carbon-X system. It serves as the command center, coordinating sensor input, device control, alarm triggers, and system-wide alerts.
Q: What types of CO₂ levels can the Carbon-X detect?
A: The system supports high-level detection up to 30,000ppm and low-level alerts starting at 5,000ppm. Both thresholds are user-adjustable to comply with local CO₂ regulations.
Q: Can the system control safety devices automatically?
A: Yes. The Carbon-X can automatically shut off CO₂ by wiring your main solenoid valve into the system. It can also control ventilation fans, dampers, and send signals to a facility’s fire alarm panel if dangerous CO₂ levels are detected.
Q: Does each zone need its own alarm?
A: Yes. Each room or area monitored by the Carbon-X must have an audio-visual alarm to notify occupants of unsafe CO₂ levels and indicate whether the area is safe to enter.
Q: Can I monitor the system remotely?
A: Absolutely. The Carbon-X system is compatible with the TrolMaster App, which allows remote monitoring and sends real-time notifications if high CO₂ levels are detected.
Q: What additional components work with the Carbon-X system?
A: Alongside the CDA-1, you can integrate CO₂ sensors, audio-visual alarms, relay modules, and shutoff devices to create a fully automated safety system tailored to your facility.
Q: Is the Carbon-X system required for CO₂-enriched grow rooms?
A: While requirements vary by region, most facilities using supplemental CO₂ are required to have an active CO₂ monitoring and alarm system—making the Carbon-X a compliant, reliable solution for safety and peace of mind.